> For the complete documentation index, see [llms.txt](https://docs.connected.events/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.connected.events/cookbook/technical-and-support-guides/event-registration-network-and-hardware-guide.md). Agents can also search and read this documentation through its [MCP server](https://docs.connected.events/~gitbook/mcp).

# Event Registration Network & Hardware Guide

A checklist and guide for planning a seamless check-in experience.

Setting up a smooth registration area depends heavily on two key elements: **hardware capacity** and **network stability**.

By calculating your hardware needs first, you can easily determine exactly how much network bandwidth you need to request from your venue or internet service provider (ISP). This guide will walk you through calculating your station count, choosing the right network configuration, and outlining technical requirements for your venue.

## Section 1: Printer & Crowd Capacity Planning

To keep wait times reasonable, you must scale your hardware (check-in stations and printers) to match your **peak arrival windows**, rather than your overall attendance.

Once you know how many stations you need, you can accurately plan your network in the next section.

### The Printer Rule of Thumb

**1 Printer & Check-in Station per 100 attendees per hour at peak arrival.**

**How to calculate this:**

Look at your busiest single hour of arrivals (usually the morning of day one, right before the opening keynote).

* **Example:** You have a major conference with **10,000 total attendees.**
* You anticipate your busiest arrival hour will see **2,000 people** show up at once.
* **Calculation:**  2,000 / 100 = 20
* **Result:** You will need a minimum of **20 printers / check-in stations** to handle this peak hour smoothly.

### Managing Large Volume Peaks: App Bookings

If your calculations show that you need more printers and stations than your budget or physical registration desk space allows, we highly recommend using our [**Bookings Feature**](https://docs.connected.events/cookbook/host-your-event/book-your-event-bookings.md)**.**

By prompting registrants to book a specific **15-minute check-in window** ahead of time, you can flatten your peak arrival curves. This distributes the crowd evenly across the morning, allowing you to run a highly successful registration desk with fewer stations, less equipment, and lower bandwidth requirements.

### Lessons Learned & Core Assumptions

To ensure your calculations translate to a seamless experience on-site, please keep these two critical operational rules in mind:

* **The 30-Second Limit:** Our capacity estimates and software systems assume an average of **under 30 seconds per attendee** for the combined check-in and physical badge assembly process. If your particular workflow requires more work—such as manual ID verification, signing physical/digital waivers on-site, taking headshots, or handling complex lanyard stuffing—your average check-in time will increase, and you will need to adjust your station estimates upward.
* **The Dedicated Helpdesk Strategy:** We strongly recommend setting up a **dedicated Helpdesk/Customer Service station** that is physically separate from your main check-in lines. If a registrant has an exception or issue (e.g., they aren't in the system, have a payment dispute, etc), immediately route them to the Helpdesk. Attempting to troubleshoot or resolve registration issues at a main check-in station halts that entire queue, rapidly creating a bottleneck for everyone behind them.

## Section 2: Choosing Your Network Configuration

We typically run our registration stations over a **wireless (Wi-Fi) network**. For maximum security and speed, we strongly prefer having a **dedicated network** for registration that is completely separate from general attendees and venue staff.

Based on the number of stations you calculated in Section 1, choose one of the three paths below:

### Option A: Small-to-Mid Events (Wireless)

* **Best for:** Events running up to **10 check-in stations**
* **Setup:** Standard Wi-Fi.
* **Bandwidth:** We recommend a general standard of **5 Mbps per device**. For a typical setup with 10 stations, you should request a dedicated network bandwidth of at least **50 Mbps** to ensure instant, lag-free data and badge printing transfers.
* **Our Recommendation:** Ask the venue for a simple, password-protected, dedicated Wi-Fi network. Sharing a network with attendees is generally ok at this scale.

### Option B: Large Events (Wireless)

* **Best for:** Large-scale events with > 10 check-in stations
* **Setup:** Dedicated high-performance Wi-Fi.
* **Our Recommendation:** Request a dedicated, password-protected SSID (network name) just for registration.
* **Important SSID Note:** The network **should not be hidden**. Hidden networks do not communicate well with the wireless cards inside Chromebooks, which can cause dropouts. Instead, keep the SSID visible but securely password-protected.
* **Dedicated Network:** Sharing a network with attendees is highly discouraged at this scale, as general web browsing will slow down the check-in process.
* **Hidden Network:** Hidden networks can cause discoverability issues with the hardware used in each check-in station.&#x20;

**Pros & Cons:**

* **Pros:**
  * **Flexible Layout:** Allows you to easily move check-in desks or change the registration layout last-minute.
  * **Rapid Scalability:** Easy to quickly add a 21st or 22nd check-in station without waiting for a technician to run new wires.
* **Cons:**
  * **Vulnerable to Interference:** High attendee density brings thousands of smartphones and devices, which can clog wireless channels and cause lag spikes.

### Option C: Large Events (Wired)

* **Best for:** Large-scale events with > 10 check-in stations and greatest stability desired
* **Setup:** Physical Ethernet cables run directly to each registration station.
* **Our Recommendation:** This is the gold standard for avoiding wireless interference. If you choose this path, you will rely on the venue's internet service provider (ISP) to physically install and route the Ethernet cables to each station.
  * *Need help?* Our team can assist with coordinating this layout. Please **contact us directly if you are going this route** so we can align on the technical details.

**Pros & Cons:**

* **Pros:**
  * **Unrivaled Reliability:** 100% immune to wireless (RF) interference. No dropped packets or sudden lag spikes.
  * **No Dropouts:** A physical copper wire connection will not randomly disconnect or drop out.
* **Cons:**
  * **Higher Cost:** Venues and ISPs charge premium labor and hardware fees to run physical lines.
  * **Rigid Setup:** Desks are anchored to where the cables are run; late layout changes require calling back venue technicians.
  * **Cable Management:** Requires physical routing and safety covers to prevent tripping hazards.

## Section 3: Important Technical Notes for Your Venue / ISP

When you submit your network request to the venue or their ISP, you can pass these exact technical requirements directly to their network engineering team to ensure our hardware works out of the box:

* **DHCP is Required:** We require **DHCP** to be enabled on our registration network. This allows our laptops, tablets, and printers to automatically assign themselves IP addresses without manual, time-consuming static configuration.
* **SSID Visibility & Naming:**
  * The network must be **broadcasted (visible)**, not hidden.
  * **Tip:** Ask the provider to add an underscore (\_) to the front of the network name (e.g., \_Registration). This forces the network to appear at the very top of the Wi-Fi list on our devices, making setup significantly faster.
  * Passwords should be secure and at least 8 characters.
* **Physical Cable Safety:** If wired connections (Option C) are used, the venue/ISP must ensure Ethernet cables do not cross open doorways or pedestrian aisles. If crossing is unavoidable, they must be safely covered with professional rubber cable ramps.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.connected.events/cookbook/technical-and-support-guides/event-registration-network-and-hardware-guide.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
